Fault maintenance strategies for ordinary machine tools and CNC machine tools
Since the 1990s, the production of CNC machine tools in China has grown rapidly at an average annual rate of 18%. Since 2002, CNC machine tools have become the mainstream equipment in China's mechanical manufacturing industry. Developed industrial countries have also listed CNC technology and equipment as strategic materials for their countries. They not only vigorously develop their own CNC technology and industry, but also implement lockdown and restriction policies on China's key high-precision CNC technologies and equipment. Therefore, vigorously developing advanced manufacturing technology with CNC technology as the core has become an important way for developed countries around the world to accelerate economic development, improve comprehensive national strength and status.
Since 2000, China's machine tool industry has been growing at a double-digit rate every year, entering a stage of rapid development, and the overall quality of the machine tool industry has improved significantly. Since 2002, China has become the world's largest consumer of machine tools for seven consecutive years. However, due to its low level of technology, low level of maintenance and troubleshooting, China's machine tool industry is "large but not strong".
1. Types of faults in ordinary machine tools and CNC machine tools
The faults of CNC machine tools are divided into two main parts: mechanical faults and electrical faults, as follows.
1.1 Mechanical faults
1.1.1 Mechanical faults of ordinary lathes
(1) When threading, the screw rotates normally and the feed box cannot move normally. When the opening and closing nut is hung in the open position, the lead screw runs empty and the slide box does not move. When the opening and closing nut is hung in the closed position, the lead screw drives the slide box to move. When the tool contacts the workpiece, the slide box cannot move normally. The movement of the slide box
It is driven by the upper and lower tiles holding the lead screw to move the slide box. When one of the tiles falls off, the lead screw drives the slide box to run. Due to the inability to contact the workpiece, the force on the slide box is relatively small, and the lead screw can also drive the slide box to move. When the turning tool contacts the workpiece, the force on the slide box is relatively large, and it will stop moving, making it impossible to process parts normally.
(2) When re cutting, the spindle speed decreases or stops on its own. When the cutting depth is too deep and the spindle speed decreases severely, it will stop and the spindle box will also be accompanied by a small amount of black smoke. The main reason is that the friction clutch of the spindle box is adjusted too loose or worn, the motor drive belt is too loose or severely worn, and the drive belt will break after severe wear.
1.1.2 Mechanical faults of CNC lathes
Many operators lack maintenance experience, especially in small-scale workshop processing. They only require the machine tool to operate without paying too much attention to maintaining the equipment, which is incorrect. Mechanical equipment, like human bodies, has a certain lifespan. As human bodies become more labor-intensive, they need to rest. After prolonged use, equipment also needs to be shut down for maintenance. If the equipment continues to operate without maintenance, the processed products will become unqualified over time and may also cause damage to the equipment.
(1) Equipment wear and tear failure. In the maintenance of CNC machine tools, some operators do not attach importance to equipment maintenance, resulting in a shorter normal wear and tear period of the equipment and unqualified products processed by the equipment. Especially for jade carving machines, the error in the processed products reaches 0.5 mm. Such a large machining error was not formed in a day, but was due to the long-term lack of maintenance of the machine tool. At the beginning, the error was relatively small, and after six months, it reached 0.5 mm.
(2) The spindle speed of the machine tool does not match the actual input code S value. When using a CNC machine tool to operate in low gear, the maximum speed in low gear is 650 r/min, but the actual speed reaches 1100 r/min.
(3) Emergency stop alarm malfunction. The emergency stop alarm cannot be eliminated after the machine tool exceeds the limit. If the over limit button is pressed and not released while pressing the reset button, the emergency stop alarm still cannot be eliminated.
1.2 Electrical faults
1.2.1 Electrical faults of ordinary lathes
The components inside the electrical cabinet of a regular lathe are relatively few, mainly including switch power supplies, contactors, relays, fuses, and other components. The circuit of a regular lathe is divided into two parts: the main circuit and the control circuit.
The control circuit for spindle rotation is prone to electrical faults, resulting in the spindle not rotating. The control circuit of the spindle mainly controls the contactor of the main circuit. When the control circuit is connected, the contactor coil on the main circuit of the spindle is energized, and then the main contact of the contactor is closed. The spindle motor is energized to start and drive the spindle to rotate. The main reason for the spindle not rotating, analyzed from the control circuit, is that the spindle start button has malfunctioned. The spindle start button is made of plastic, and some parts of the button switch are made of thin-walled technology, so over time, the button switch is prone to aging, and the thin-walled parts are prone to breakage. The button switch of a regular lathe is frequently used, which also shortens the service life of the button switch.
1.2.2 Electrical faults of CNC lathes
The most common location for electrical failures in CNC lathes is the four station tool holder, which can cause malfunctions such as the tool holder not being able to find the tool position, not being able to lock the alarm, and not being able to start the alarm normally. Taking the production of machine tools by Dalian Machine Tool Factory as an example, a brief introduction is given. When a certain tool position is needed on a CNC lathe, the corresponding transmitter will have a signal. The positions of the sending tray and magnetic steel should correspond. If the positions of the sending tray and magnetic steel cannot be completely matched, two situations will occur. The first scenario is that the tool holder will continue to rotate and cannot find its own position, resulting in a machine tool alarm and tool change timeout; The second scenario is that the tool holder can rotate normally and lock the rotating blade in reverse, but the position of the tool holder is incorrect. In addition, the monitor is also prone to malfunctions, such as not lighting up when the machine tool monitor is powered on, and even the words on the monitor cannot be seen clearly. Such faults can affect the normal operation of CNC machine tools and even lead to a shortened service life of the equipment.
2. Maintenance strategies for common machine tool malfunctions
The use of mechanical equipment has a lifespan, which means that the equipment also has a lifespan. When repairing equipment, one can see as a person diagnosing the illness, observing, smelling, and cutting the equipment. "Wang" means observing the equipment first, mainly observing the model, system, panel, etc. of the equipment. "Wen" is to listen to the sound of the device's operation. During maintenance, "Wen" is placed at the last step. After consulting the operator, it can make the correct judgment before turning on and starting the device to listen for any abnormal sounds. "Cutting" means touching the device with your hand to determine if it is heating or not.
There are various maintenance methods for equipment, and specific analysis should be conducted based on the specific situation. After using the lathe for a long time, various components begin to age, and the wire ends become loose and broken, leading to electric leakage. The leakage protection measures for the equipment are still in place. When the control circuit of the machine tool leaks electricity, the machine tool insurance will come into effect. When searching for a circuit, the first step is to locate the fuse according to the circuit diagram. You can use a multimeter to measure whether the resistance of the fuse is open or infinite, in order to determine whether the fuse is burnt out. After replacing the fuse, the spindle will resume normal rotation. If the fuse burns out again after a short period of use, it is necessary to check the leakage point of the circuit and completely solve the problem.
2.1 Maintenance methods for mechanical faults in ordinary machine tools
(1) Repair method for the inability of the feed box to move properly when the screw rotates normally during threading. To open the slide box and inspect the tiles, if one tile falls off, the screw can drive the slide box when the parts are not being processed. When the turning tool starts processing, the screw rotates normally but the slide box does not move. To address this, it is necessary to adjust the friction clutch, grind or replace the friction plates, tighten the drive belt appropriately, or replace the severely worn drive belt.
(2) The maintenance method for reducing the spindle speed or self stopping during heavy cutting. The tightness of the motor drive belt should be checked and adjusted; Adjust the clearance between the friction plates of the friction clutch again. If there are still problems, the wear of the relevant components should be checked. If the wear is severe, it is necessary to repair or replace the corresponding components.
2.2 Maintenance methods for electrical faults in ordinary machine tools
Taking the ordinary lathe of Dalian Machine Tool Group Co., Ltd. as an example, this article introduces the maintenance methods for electrical faults.
(1) Repair method for quick button malfunction of lathe. The quick button of the lathe is located at the end of the operating handle, and when the handle is moved, the bed saddle and small skateboard move. Press the fast button while the bed saddle is moving, and the bed saddle will move quickly to increase efficiency. The position of the quick button design is reasonable, but the design of the handle is flawed. The wiring inside the handle is prone to detachment or the wires inside are prone to breakage, resulting in leakage. Leakage will first burn out the fuse. After the fuse is burned out, the spindle cannot operate normally, but the machine tool display light shows that the machine tool is powered. At this time, the fuse should be replaced and the leakage point should be insulated with tape to restore the machine tool to normal.
(2) Repair method for emergency stop button malfunction. The emergency stop button is fixed on the lathe like the start button, and the fixed end may become loose or even break over time. Therefore, the emergency stop button is also an important part of mechanical equipment that is prone to malfunctions in the later stage. When using the emergency stop button, attention should be paid to whether the button is loose. If it is loose, it should be tightened immediately.
3. Maintenance Strategies for CNC Machine Tool Faults
3.1 Maintenance methods for mechanical faults in CNC machine tools
(1) Maintenance methods for equipment wear and tear. After the equipment wears out, lubricating oil needs to be used for timely maintenance. If the wear is severe, it is necessary to repair the worn area or directly replace the corresponding components.
(2) Repair method for inconsistency between the spindle speed of the machine tool and the actual input code S value. It is necessary to check whether the high and low speed gear lever is in position, and check the PMC signal display status to directly observe whether the gear lever is in place. The steps are as follows: First, press the system button to open the system parameters, press the PMC soft key to find the PMCDGN soft key, press the PMCDGN soft key to find the STATUS soft key, press the STATUS soft key to display the detection screen and find the X3.4 and X3.5 bits, and check the signal changes of the input bits. When the gear is shifted to 75-830-2500, the status of X3.4 is displayed as 1, and the status of X3.5 is displayed as 0; When the gear is shifted to 20-216-650, the X3.4 position status displays 0, and the X3.5 position status displays 1. If X3.4 and X3.5 are both 0, in neutral position, and X3.4 and X3.5 are both 1, there will be a discrepancy between the code S value and the actual speed. At this time, it is necessary to repeatedly shift to high and low gear positions until the PMC monitoring signal is correct and the spindle speed code S value is consistent with the actual speed. If the problem cannot be solved by repeatedly shifting gears, the sensor position needs to be changed.
(3) Repair methods for emergency stop alarm faults. The emergency stop alarm of CNC machine tools includes pressing the emergency stop button and overtravel alarm. As long as the emergency stop button is pressed or the machine tool workbench exceeds the set stroke, the machine tool will stop running. Hard limit switch is a limit switch that can be set by changing the position of the limit switch. When the hard limit of the machine tool is activated, the alarm can be eliminated by pressing the over travel button on the machine tool panel. Press the over travel button without releasing it, and then press the reset button simultaneously. At this time, the emergency stop alarm will not be displayed. Move the workbench away from the limit switch and release the over travel release button, and the machine tool alarm will be completely eliminated. When the internal part of the hard limit switch is filled with chips and the switch's movable contacts are pressed, they cannot bounce up normally. At this time, the machine tool emergency stop cannot be eliminated normally. It is necessary to check the limit switch to clean the chips inside the switch, reset the contacts, and restore normal use of the limit switch. The emergency stop alarm is eliminated.
3.2 Maintenance methods for motor faults in CNC machine tools
3.2.1 Maintenance of four station tool holder faults
Long term use of machine tools can cause some screws to loosen, especially in the frequently moving parts. The knife holder is one of them. When the knife holder keeps rotating and cannot find the cutting position, it is necessary to open the upper cover of the knife holder and check if the sender tray is loose. You can touch the circular sender tray with your hand. If the transmitter is loose, you can tighten the fastening nut on top. When tightening the nut, adjust the position of the transmitter slightly, and then change the tool in MDI mode to see if it is normal. If it is not normal, rotate the transmitter in the opposite position until the correct position is found.
If the tray is not loose, observe if it is burnt out. It is possible to observe with the naked eye whether there is any blackening in the sender's tray. If the sender's tray is blackened, it indicates that it has been burned out, and at this point, the sender's tray has no repair value and can be replaced directly. In addition, you can also observe whether the wiring terminals of the transmitter are loose or loose, and tighten the wiring in a timely manner.
3.2.2 System Panel Display Fault Repair
Most mechanical equipment is equipped with a display, which can display the working coordinates and running programs of the mechanical equipment. So the power supply for the display is provided by a switching power supply. The input voltage of the switching power supply is 220 V AC voltage, and the output voltage can be 110 V AC voltage or 24 V DC voltage. The power supply voltage for the display is 24 V. When using mechanical equipment, if the display shows that there is power but the brightness is not enough or not at all, it is necessary to check the power switch. Measure the input voltage of the monitor with a multimeter. If it is below 20 V, the monitor will not display the screen. You can adjust the output voltage of the switch power supply to a value greater than or equal to 20 V, and the display will return to normal. The low voltage of the switching power supply is generally caused by humid air, so it is necessary to maintain ventilation and dryness in the electrical cabinet. If the input voltage of the monitor is greater than or equal to 20 V, other reasons need to be investigated.
4. Conclusion
In order to reduce the failure rate of machine tools, the correct policy for the use and maintenance of machine tools is to prioritize prevention and combine maintenance and repair. According to the fault characteristic curve of mechanical equipment - "bathtub curve", planned maintenance, inspection, and repair of machine tools to prevent sharp wear and tear is a correct repair system. In addition, technical maintenance personnel should have a clear understanding of the fault characteristics and maintenance strategies of ordinary lathes and CNC lathes, take timely and correct maintenance measures for equipment that has malfunctioned, avoid equipment operating with defects, and safeguard the production of the enterprise.